RANCANG BANGUN ALAT UJI PRESTASI MOTOR 3 FASA DENGAN MENGGUNAKAN INVERTER VFD JENIS XYS-AT1 (MODEL AT1-1500X) DAN PEMBEBANAN TAMBAHAN DENGAN SISTEM REM HIDROLIK

Authors

  • Dudi Suparyogi Jurusan Teknik Mesin, Fakultas Teknologi Industri, Universitas Kebangsaan Republik Indonesia
  • Ade Buhori Jurusan Teknik Mesin, Fakultas Teknologi Industri, Universitas Kebangsaan Republik Indonesia

Keywords:

Inverter, Efficiency, Electric Power, Motor, Cheap

Abstract

The 3-phase motor performance test equipment with rotation adjustment using the inverter model AT1-1500X and additional loading with a hydraulic brake system is designed in such a way as to obtain representative experimental data so that it can be used as a reference to implementations in real life because this tool can optimize the use of power so that the electricity used will be less than not using the tool, or in other words the efficiency of using electric power while slowing down the damage to the tool used, whether it is a motor as a driver or a tools that is drive like a motor or a load other tools used can be easily adjusted the rotational speed and torque as needed by simply changing the frequency value (Hz) via a potentiometer switch installed on the panel, the operating pattern mentioned above is the main factor in the process of creating efficient use of electric power and inverters with single phase input and 3-phase output can be used at home where the inverter can operate a 1-phase motor by simply connecting the "W" terminal as phase and "U" as neutral so that home appliances can be regulated using electric power to make it more economical and cheap to finance

References

David H. Sirait, 2008 : Analisis Starting Motor Induksi Tiga Phasa pada PT.

Berlian Unggas SaktiTj. Morawa.

Sularso,Kyokatsu Suga Cet.10-Jakarta: Pradnya Paramita, 2002 Dasar perencanaan dan pemilihan element mesin

Himsar Ambarita (2011). Perpindahan Panas Konveksi dan Pengantar ALat Penukar Kalor. Jurnal Perpindahan Panas Volume 9, No. 1 April 2012.

Hazwi, 2010. Perancangan dan Pembuatan Alat Penguji Tekan (hidraulic screw press) Pada Proses Pengolahan Minyak Kelapa. http: repository.usu.ac.id.pdf. [16 Februari 2015].

http://www.mhtlab.uwaterloo.ca (tabel property value of dry air at 1 atm pressure

http://elektro-unimal.blogspot.com/2013/05/konstruksi-motor-listrik-3-fasa.html

https://gearmotorindo.com/pengertian-motor-listrik-3-phase-terdiri-dari-komponen-komponen/

http://sisfo.itp.ac.id/bahanajar/ Bahan Ajar/Zuriman Anthony

https://jawabanapapun.com/apa-itu-rotor-belitan/

https://repository.usm.ac.id/ Analisa Pengaruh Pembebanan Terhadap Parameter Listrik Dan Harmonisa Motor Induksi Tiga Fasa Sebagai Penggerak Elevator Gedung Kasuari Pt. Multi Prada Mandiri

J. P. Holman. alih bahasa oleh Ir. E. Jasjfi M.Sc, 1994, Manual Book, Perpindahan Kalor, Erlangga, Jakarta.

Jurnal Haris Mahmudi, Analisa perhitungan Pulley dan V belt pada sistem transmissi mesin pencacah

Prasetya, Ria, Analisis Penghematan Energi Pada Pompa Fasum Menggunakan Variable Speed Drive, UGM, 2013

Schneider Electric, “Characteristic Variable Speed Drive”. Training efisiensi energi

Sularso Haruo Tahara, Pompa Dan Kompresor. Pemilihan, Pemakaian, Dan Pemeliharaan. Jakarta: Pradnya Paramitha. 1994

Downloads

Published

2024-12-06

How to Cite

Dudi Suparyogi, & Ade Buhori. (2024). RANCANG BANGUN ALAT UJI PRESTASI MOTOR 3 FASA DENGAN MENGGUNAKAN INVERTER VFD JENIS XYS-AT1 (MODEL AT1-1500X) DAN PEMBEBANAN TAMBAHAN DENGAN SISTEM REM HIDROLIK . Journal of Innovation Research and Knowledge, 4(7), 4669–4684. Retrieved from https://mail.bajangjournal.com/index.php/JIRK/article/view/9118

Issue

Section

Articles